EnterasysKeller

From LLL
Revision as of 14:59, 2 November 2007 by AlainKnaff (talk | contribs) (Import from phpWiki)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

This description assumes that server's external port is fe.1.2, the fiber optic is ge.1.2 and the server's internal port fe.1.1 (as seen in Hosingen)


  • Connect to Switch as descibed in EnterasysGeneralities
  • Assign the IP address: set ip address 10.0.90.1 mask 255.0.0.0
  • Configure VLAN 1
set vlan name     1 Internal
set vlan egress   1 ge.1.1    untagged
set vlan egress   1 ge.1.2    tagged
set vlan egress   1 fe.1.1    untagged
clear vlan egress 1 fe.1.2
set vlan egress   1 fe.1.3-48 untagged

This sets all ports except fiber-optic to untagged, and removes external port altogether from internal VLAN

  • Create VLAN 2
set vlan          2 create
set vlan name     2 External
set port vlan     fe.1.2 2
set vlan egress   2 ge.1.2   tagged
set vlan egress   2 fe.1.2   untagged